Properties
Strong chemical adhesion
Fluoride release
Low sensitivity to
moisture
Blue color for good
visibility
Indications
Bonding orthodontic bands
Contents
POWDER 16g
LIQUID 12g
Measuring Spoon
Mixing Pad
Instructions for Use
Storage
Store at a temperature of
approximately 4-25°C (39-77°F)
Shelf life
2 years
Warning
Liquid and mixed cement
are corrosive.
1) In case of contact with
oral tissue or skin, remove immediately with cotton wool soaked in
alcohol. Flush with water.
2) In case of contact with
eyes, flush immediately with water and seek medical attention.
3) DO NOT mix powder or
liquid with glass ionomer components from any other
system.
4) Direct contact with
eugenol-based products is to be avoided. Eugenol inhibits the setting
of Glass Ionomer sealers.
Instructions for use
Tooth preparation
Clean the tooth surface
with pumice and water, prophy cup or brush
Mixing
Fluff the powder bottle
before dispensing by shaking in an up and down motion for 5 seconds.
The recommended Powder : Liquid ratio is 1 orange scoop of powder to
4 drops of liquid. This is equivalent to a P:L ratio of 0.20g/0.11g.
Shake the liquid bottle
also before dispensing.
For accurate dispensing of
the liquid, hold the liquid bottle vertically upside down. Allow air
bubbles to escape before dripping. If the liquid clogs at the top of
the nozzle, remove it with damp gauze to dispense correctly next
time.
Discard non-full drops
(drops with air bubbles) of liquid.
After use, tightly close
both liquid and powder bottles to prevent exposure to moisture.
Mixing time
Place one level scoop of
powder and four drops of liquid onto the paper pad. Divide the powder
into two equal parts with the plastic spatula. Incorporate the first
portion into the liquid, and mix for about 10 seconds. Add the second
part and mix the whole for 10-15 seconds. Total mixing time should
not exceed 20-25 seconds. The material is designed for use at room
temperatures of 21-25°C (69.8-77.0°F).
Working time
The working time is 3
minutes from the onset of mixing at 23°C (73.4°F).
Higher temperatures or
increased powder: liquid will shorten the working time, and lower
temperatures will delay it.
Band cementation
Place cement on interior
of band in the usual manner. Seat band on tooth. Remove excess
cement. Wires can be attached after a setting time of 5 minutes.
|